Arb RD82 Manuel d'utilisateur Page 36

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 35
7 Testing & Final Assembly
34
Turn the ignition to the ‘ON’ position (leaving the motor off). The
large illuminating symbol on the Air Locker switch cover should be
‘OFF’.
Turn the compressor (or alternate air source) on to charge the air
supply up to its maximum pressure.
Rotate one wheel by hand.
The wheel should rotate freely and the opposite wheel should be
turning in the opposite direction without any resistance or
mechanical noise from within the differential.
Turn the Air Locker switch to the ‘ON’ position. The illuminated
symbol on the switch cover should light up.
Rotate the same wheel again.
Both wheels should rotate together.
Turn the switch off again.
Rotate the same wheel.
The wheels should again rotate in opposite directions.
7.3
Re-Sealing & Filling the Differential
NOTE : Consult the ARB Air Locker Operating & Service
Manual for recommendations on differential lubricant
specifications.
Replace the differential cover using gasket sealant or a standard
differential cover gasket for your make of vehicle.
Refill the differential until level with the filler hole.
Rotate the differential center 2 full turns.
Check the oil level and refill if necessary.
Replace filler plug (apply thread sealant to filler plug before
inserting if it is a threaded type plug).
Wipe differential housing clean of any oil or grease which may
collect dirt or other abrasive particles.
Vue de la page 35
1 2 ... 31 32 33 34 35 36 37 38 39 40

Commentaires sur ces manuels

Pas de commentaire